Shanghai Liguan Electromechanical Equipment Co., Ltd. is a professional sales company for XFC-2200 vortex air pump. The products have the characteristics of fast delivery, low noise and so on. The full copper motor is adopted, which not only makes the air pump run smoothly, but also has a high-end appearance. Welcome sincere people to join and create brilliance together.
XFC-2200 vortex air pump operation
1. Close the air inlet before starting the fan.
2. Check whether all parts of the fan are normal.
3. After the fan runs under the specified load for a period of time, check whether the bearing temperature is normal. When there is no special requirement for bearing temperature, the bearing temperature rise generally shall not be higher than 40℃ of the ambient temperature.

Applications of air pump
Powder and granular material conveying, textile machinery dust collection, cloth cutting machine air cushion, sewage treatment aeration, paper pulp dewatering, glass industry and ice factory air pump, tunnel engineering air pressure delivery, aquaculture oxygen supply and so on.
XFC-2200 vortex air pump features
1. High pressure, large air volume, low noise and light weight.
2. Made of aluminum alloy, which greatly reduces the weight and achieves the purpose of light weight.
3. The motor is a fully enclosed external fan type aluminum frame motor with special shaft design, which can be used for a long time.
4. Special blade design with high pressure, large air volume, low noise and long service life.
5. Special air volume regulating damper with high stability of air volume control and easy operation.
6. Complete styles, large inventory and fast delivery.
Precautions
1. Overload will occur when fully closed.
2. Overload will occur when fully open. At this time, use an ammeter to confirm the current and adjust the buffer. Generally, use it within the rated current.
3. Repeatedly turning the switch on and off within one minute will cause the motor to overheat, which should be avoided.
4. Inverter control - When using the inverter, the power waveform is distorted, the motor makes loud noise and vibrates greatly. If the temperature rises or the vibration is large when running with the inverter, stop the operation. Generally, please use it under the following conditions.
5. The maximum frequency value (rotating speed) must be within the frequency specified on the label and within the rated current.
6. The minimum frequency (rotating speed) shall be above 30 Hz and within the rated current.
7. Single-phase motors cannot be operated with inverters.
Principle
When XFC-2200 vortex air pump the impeller rotates, due to centrifugal force, the wind vane promotes the gas to move forward and outward, forming a series of spiral movements. The air between the impeller blades spirally accelerates and rotates, and squeezes the gas outside the pump body into the side groove. When it enters the second side channel, the gas is compressed, and then accelerates and rotates again between the impeller blades. When the air passes through the impeller and the side groove along a spiral track, each impeller blade increases the degree of compression and acceleration. With the rotation, the kinetic energy of the gas increases, further increasing the pressure of the gas passing through the side channel. When the air reaches the connection point between the side groove and the discharge flange, the gas is squeezed out of the blades and passes through the air outlet.